Open Access Research Article

Assessing Fracture Resistance of non Vital Teeth Using Two Different Composite Systems: Short-Fibre-Reinforced Composite and Glass Fibre Post with Microfilled Hybrid Composite

SANDA ILEANA CIMPEAN, IOANA-SOFIA POP-CIUTRILA, SMARANDA BUDURU, LILIANA LACRAMIOARA PAVEL, DANIELA FLORENTINA FLOREA, ADA GABRIELA DELEAN, MARIOARA MOLDOVAN, MIRCEA CRISTIAN DUDESCU, SORIN BERBECE, DOINA CARINA VOINESCU, ADRIAN BEZNEA, MARIUS NEGUCIOIU, VICTORITA STEFANESCU
Published 06 Jan 2021
Pages 286–296

Abstract

Posterior endodontically treated teeth are exposed to risk fracture due to the great masticatory forces developed in the area. Fiberglass posts are considered a practical solution for such situations, but their main disadvantage yet remains the poor adhesion to the remaining tooth structures. The purpose of the present study was to evaluate a material that could replace the use of fiberglass posts on posterior teeth. 32 premolars were selected and divided into 4 groups (n=8): the first group was considered the control group; the second group was composed of endodontically treated teeth that were filled with gutta-percha, but without any coronal restoration; the third group was composed of teeth that received the same endodontic treatment as in the second group but were restored with a fibreglass post and a light cured microfilled hybrid composite material; the fourth group was similar to the third one, except teeth were restored with a short-fibre-reinforced composite (EverX Posterior, GC Europe N.V., Leuven, Belgium) and a microfilled hybrid composite over it. The fracture resistance of all the teeth was tested using a universal testing device. One-way ANOVA and the Tukey post-hoc variation tests for multiple comparisons were used to analyze the results. The short-fibre-reinforced composite material increased the fracture resistance of endodontically treated teeth (1159.42 N), twice as much as that obtained by using fiberglass posts (522.35 N)). Within the limitations of the present study, EverX Posterior represents a better alternative compared to fiberglass posts in the crown and root reconstruction of posterior endodontically treated teeth.

Keywords: EverX Posterior; post; fiberglass; endodontic treatment; dental fracture

How to Cite this Article

CIMPEAN, S., POP-CIUTRILA, I., BUDURU, S., PAVEL, L., FLOREA, D., DELEAN, A., MOLDOVAN, M., DUDESCU, M., BERBECE, S., VOINESCU, D., BEZNEA, A., NEGUCIOIU, M., & STEFANESCU, V. (2021). Assessing Fracture Resistance of non Vital Teeth Using Two Different Composite Systems: Short-Fibre-Reinforced Composite and Glass Fibre Post with Microfilled Hybrid Composite. Materiale Plastice, 57(4), 286–296. https://doi.org/10.37358/MP.20.4.5427
CIMPEAN S, POP-CIUTRILA I, BUDURU S, PAVEL L, FLOREA D, DELEAN A, MOLDOVAN M, DUDESCU M, BERBECE S, VOINESCU D, BEZNEA A, NEGUCIOIU M, STEFANESCU V. Assessing Fracture Resistance of non Vital Teeth Using Two Different Composite Systems: Short-Fibre-Reinforced Composite and Glass Fibre Post with Microfilled Hybrid Composite. Materiale Plastice. 2021;57(4):286–296. doi: 10.37358/MP.20.4.5427
S. CIMPEAN, I. POP-CIUTRILA, S. BUDURU, L. PAVEL, D. FLOREA, A. DELEAN, M. MOLDOVAN, M. DUDESCU, S. BERBECE, D. VOINESCU, A. BEZNEA, M. NEGUCIOIU, and V. STEFANESCU, "Assessing Fracture Resistance of non Vital Teeth Using Two Different Composite Systems: Short-Fibre-Reinforced Composite and Glass Fibre Post with Microfilled Hybrid Composite,” Materiale Plastice, vol. 57, no. 4, pp. 286–296, 2021. doi: 10.37358/MP.20.4.5427
✓ Copied to clipboard