Open Access Research Article

Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses

DANIEL ALEXANDRU POP, R. MALAESCU, LIVIU MARSAVINA, TIBERIU HOSSZU, RAUL ROTAR, LUCIANA GOGUTA, VIRGIL FLORIN DUMA, MEDA LAVINIA NEGRUTIU, COSMIN SINESCU, ANCA JIVANESCU
Published 30 Sep 2018
Pages 361–363

Abstract

The aim of this in vitro study is to compare the load-to-fracture performance of polymethyl methacrylates (PMMA) provisional restorations manufactured with a traditional laboratory technique in comparison to a computer-assisted design and computer-assisted manufacturing (CAD-CAM) technique. Five interim three-unit fixed dental prostheses were fabricated with the conventional indirect technique, on a standard typodont. The same model was scanned with an intraoral scanner and the digital design of identical fixed dental prostheses was made. Then other five interim three-unit fixed dental prostheses were milled from PMMA CAD/CAM blocks with an in office milling machine. All specimens were tested for flexural strength in a universal testing machine, and the maximum load to fracture was measured. For the conventional provisional restorations, the load to fracture was 121.16 ± 24.6, in comparison to CAD/CAM interim restorations, for which the load to fracture was 728.88 ± 228.7. Within the limitations of this study, one can conclude that CAD/CAM provisional restorations present a higher fracture load than the conventional manufactured interim restorations.

Keywords: interim restorations; polymethyl methacrilat (PMMA); computer-assisted design (CAD); computer-assisted manufacturing (CAM); load to fracture

How to Cite this Article

POP, D., MALAESCU, R., MARSAVINA, L., HOSSZU, T., ROTAR, R., GOGUTA, L., DUMA, V., NEGRUTIU, M., SINESCU, C., & JIVANESCU, A. (2018). Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses. Materiale Plastice, 55(3), 361–363. https://doi.org/10.37358/MP.18.3.5030
POP D, MALAESCU R, MARSAVINA L, HOSSZU T, ROTAR R, GOGUTA L, DUMA V, NEGRUTIU M, SINESCU C, JIVANESCU A. Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses. Materiale Plastice. 2018;55(3):361–363. doi: 10.37358/MP.18.3.5030
D. POP, R. MALAESCU, L. MARSAVINA, T. HOSSZU, R. ROTAR, L. GOGUTA, V. DUMA, M. NEGRUTIU, C. SINESCU, and A. JIVANESCU, "Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses,” Materiale Plastice, vol. 55, no. 3, pp. 361–363, 2018. doi: 10.37358/MP.18.3.5030
✓ Copied to clipboard