Abstract

Post and core build-ups provide resilience and retention for future tooth restorations. In this study we intend to assess the resistance to fracture of two types of aesthetic post, using a testing machine after the application of a paraxial force. The results show that no specific material from the ones used shows a better behavior. Fiber quartz posts AAA Fiber Post had the highest resistance and the fiberglass posts Matrix Plus 2 were rated with the lowest values. Further laboratory and clinical studies are necessary to the in which one type of post material is favorable for a specific type case.

Keywords: fiber post material; crown reconstruction; bending resistance

How to Cite this Article

IONAS, M., PAUN, A., & FRATILA, M. (2017). Influence of the Fiber Post Material on the Reconstructed Tooth Crown Bending Resistance. Materiale Plastice, 54(1), 45–47. https://doi.org/10.37358/MP.17.1.4782
IONAS M, PAUN A, FRATILA M. Influence of the Fiber Post Material on the Reconstructed Tooth Crown Bending Resistance. Materiale Plastice. 2017;54(1):45–47. doi: 10.37358/MP.17.1.4782
M. IONAS, A. PAUN, and M. FRATILA, "Influence of the Fiber Post Material on the Reconstructed Tooth Crown Bending Resistance,” Materiale Plastice, vol. 54, no. 1, pp. 45–47, 2017. doi: 10.37358/MP.17.1.4782