ABOUT INDEXING EDITORIAL BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER NEWS, EVENTS AUTHOR'S PAGE CONTACT
Materiale Plastice
Cite as: Mater. Plast.
https://doi.org/10.37358/Mat.Plast.1964

OSIM Nr. R102356
ISSN Print 0025-5289
ISSN Online 2668-8220
Materiale Plastice - Latest Issue

Latest Issue >>>
ARCHIVES
   Volume 60, 2023
   Volume 59, 2022
   Volume 58, 2021
   Volume 57, 2020
   Volume 56, 2019
   Volume 55, 2018
   Volume 54, 2017
   Volume 53, 2016
   Volume 52, 2015
   Volume 51, 2014
   Volume 50, 2013
   Volume 49, 2012
   Volume 48, 2011
   Volume 47, 2010
   Volume 46, 2009
   Volume 45, 2008
   Volume 44, 2007
   Volume 43, 2006
   Volume 42, 2005
   Volume 41, 2004
   Volume 40, 2003
 
<<<< back

Materiale Plastice (Mater. Plast.), Year 2018, Volume 55, Issue 4, 606-608

https://doi.org/10.37358/MP.18.4.5084

Denisa Maria Golban, Radu Negru, Camelia Szuhanek, Meda Lavinia Negrutiu, Liviu Marsavina, Virgil Florin Duma, Cosmin Sinescu, Liliana Porojan

Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations


Abstract:
Flash-Free Orthodontic Adhesive System represents the latest technology in the field of orthodontics. In the present study the bonding technique is applied on CAD/CAM produced resin crowns. Ten resin blocks were shaped after an upper premolar crown design from the 3Shape Library, and they were divided ino two groups: on Group 1, control, Clarity Advanced braces (3M Unitek, Monrovia, CA, USA) were bonded using XT Adhesive Paste (3M Unitek, Monrovia, CA, USA), while on Groups 2 same aesthetic brackets were applied, using the APC Flash-Free Adhesive Coated Appliance System (3M Unitek, Monrovia, CA, USA). Bracket positioning time was recorded for each sample. Zwick Zoel Z005 testing machine was used to measure the shear bond strength (SBS) at which debonding takes place. Adhesive remnant index (ARI) was registered, as well as presence or absence of adhesive flash and accuracy of flash cleaning before curing. Group 1 showed a mean bonding time of 46.4 s, while Group 2 needed about 20.6 s for each bracket bonding. Mean SBS values for both groups are considered clinically acceptable (6.27 MPa for Group 1 and 7.77 MPa for Group 2). ARI scores were zero for all samples and after debonding, on group 1 can be observed the adhesive flash. In conclusion, APC Flash-Free Coated Appliance System showed reduced time for bracket positioning compared to the conventional technique. APC Flash-Free System showed acceptable SBS values, higher than the uncoated brackets. No composite was left on the resin crown after debonding, the adhesive flash resulted in the conventional technique remaining on the edges of the debonded brackets.


Keywords:
APC Flash-Free; CAD/CAM produced resin restoration; bonding time; shear bond strength (SBS); adhesive remnant index

Issue: 2018 Volume 55, Issue 4
Pages: 606-608
Publication date: 2018/12/30
https://doi.org/10.37358/MP.18.4.5084
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
GOLBAN, D.M., NEGRU, R., SZUHANEK, C., NEGRUTIU, M.L., MARSAVINA, L., DUMA, V.F., SINESCU, C., POROJAN, L., Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations, Mater. Plast., 55(4), 2018, 606-608. https://doi.org/10.37358/MP.18.4.5084

Vancouver
Golban DM, Negru R, Szuhanek C, Negrutiu ML, Marsavina L, Duma VF, Sinescu C, Porojan L. Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations. Mater. Plast.[internet]. 2018 Dec;55(4):606-608. Available from: https://doi.org/10.37358/MP.18.4.5084


APA 6th edition
Golban, D.M., Negru, R., Szuhanek, C., Negrutiu, M.L., Marsavina, L., Duma, V.F., Sinescu, C. & Porojan, L. (2018). Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations. Materiale Plastice, 55(4), 606-608. https://doi.org/10.37358/MP.18.4.5084


Harvard
Golban, D.M., Negru, R., Szuhanek, C., Negrutiu, M.L., Marsavina, L., Duma, V.F., Sinescu, C., Porojan, L. (2018). 'Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations', Materiale Plastice, 55(4), pp. 606-608. https://doi.org/10.37358/MP.18.4.5084


IEEE
D.M. Golban, R. Negru, C. Szuhanek, M.L. Negrutiu, L. Marsavina, V.F. Duma, C. Sinescu, L. Porojan, "Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations". Materiale Plastice, vol. 55, no. 4, pp. 606-608, 2018. [online]. https://doi.org/10.37358/MP.18.4.5084


Text
Denisa Maria Golban, Radu Negru, Camelia Szuhanek, Meda Lavinia Negrutiu, Liviu Marsavina, Virgil Florin Duma, Cosmin Sinescu, Liliana Porojan,
Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations,
Materiale Plastice,
Volume 55, Issue 4,
2018,
Pages 606-608,
ISSN 2668-8220,
https://doi.org/10.37358/MP.18.4.5084.
(https://revmaterialeplastice.ro/Articles.asp?ID=5084)
Keywords: APC Flash-Free; CAD/CAM produced resin restoration; bonding time; shear bond strength (SBS); adhesive remnant index


RIS
TY - JOUR
T1 - Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations
A1 - Golban, Denisa Maria
A2 - Negru, Radu
A3 - Szuhanek, Camelia
A4 - Negrutiu, Meda Lavinia
A5 - Marsavina, Liviu
A6 - Duma, Virgil Florin
A7 - Sinescu, Cosmin
A8 - Porojan, Liliana
JF - Materiale Plastice
JO - Mater. Plast.
PB - Materiale Plastice SRL
SN - 2668-8220
Y1 - 2018
VL - 55
IS - 4
SP - 606
EP - 608
UR - https://doi.org/10.37358/MP.18.4.5084
KW - APC Flash-Free
KW - CAD/CAM produced resin restoration
KW - bonding time
KW - shear bond strength (SBS)
KW - adhesive remnant index
ER -


BibTex
@article{MatPlast2018P606,
author = {Golban Denisa Maria and Negru Radu and Szuhanek Camelia and Negrutiu Meda Lavinia and Marsavina Liviu and Duma Virgil Florin and Sinescu Cosmin and Porojan Liliana},
title = {Flash-Free Orthodontic Adhesive System Bonded on CAD/CAM Produced Resin Restorations},
journal = {Materiale Plastice},
volume = {55},
number = {4},
pages = {606-608},
year = {2018},
issn = {2668-8220},
doi = {https://doi.org/10.37358/MP.18.4.5084},
url = {https://revmaterialeplastice.ro/Articles.asp?ID=5084}
}


Downloads number: 0
<<<< back
 
  Search Authors
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License