Materiale Plastice (Mater. Plast.), Year 2018, Volume 55, Issue 1, 85-90

https://doi.org/10.37358/MP.18.1.4969

Constantin Nanu, Ion Poeata, Cezar Popescu, Lucian Eva, Bogdan Florin Toma, Stefan Lucian Toma

The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses


Abstract:
The aim of the paper is to identify the of optimal plastic type used in obtaining thoraco-lumbar orthoses - used in the treatments of comminutive fracture, of burst fracture type of the vertebrae in the lumbar area. For this purpose, with the help of Finite Element Analysis (FEA), a theoretical study was carried out on the influence of elastic properties of plastics, used in the achieving of lumbar orthoses, on the state of tension and on the local displacements of the bone fragments from the traumatized area under the condition of the movement from the base of extension and flexion. In the study the force of flexion, the force of extension and the elastic modulus of plastic material varied on three levels. The theoretical results obtained were completed with clinical trials carried out on a total of 26 patients who suffer thoraco-lumbar comminutive fracture, burst fractures type, at vertebra T11 and were immobilized in Boston-type plastic orthoses made of: polypropylene (PP), rigid vinyl polychloride (PVC-D) and polytetrafluoroethylene (PTFE). As a result of observations, it was found that the use of an orthesis made from rigid plastic material, although it appears higher stresses in the traumatized zone, the displacements of bone fragments are smaller, the pains is higher in the fractured zone, the angle of kyphosis (LKA) close to the normal value and a better mobility of the spine (ODI indicator).


Keywords:
Spine; Boston orthosis; polypropylene; vertebra

Issue: 2018 Volume 55, Issue 1
Pages: 85-90
Publication date: 2018/3/30
https://doi.org/10.37358/MP.18.1.4969
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
NANU, C., POEATA, I., POPESCU, C., EVA, L., TOMA, B.F., TOMA, S.L., The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses, Mater. Plast., 55(1), 2018, 85-90. https://doi.org/10.37358/MP.18.1.4969

Vancouver
Nanu C, Poeata I, Popescu C, Eva L, Toma BF, Toma SL. The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses. Mater. Plast.[internet]. 2018 Jan;55(1):85-90. Available from: https://doi.org/10.37358/MP.18.1.4969


APA 6th edition
Nanu, C., Poeata, I., Popescu, C., Eva, L., Toma, B.F. & Toma, S.L. (2018). The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses. Materiale Plastice, 55(1), 85-90. https://doi.org/10.37358/MP.18.1.4969


Harvard
Nanu, C., Poeata, I., Popescu, C., Eva, L., Toma, B.F., Toma, S.L. (2018). 'The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses', Materiale Plastice, 55(1), pp. 85-90. https://doi.org/10.37358/MP.18.1.4969


IEEE
C. Nanu, I. Poeata, C. Popescu, L. Eva, B.F. Toma, S.L. Toma, "The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses". Materiale Plastice, vol. 55, no. 1, pp. 85-90, 2018. [online]. https://doi.org/10.37358/MP.18.1.4969


Text
Constantin Nanu, Ion Poeata, Cezar Popescu, Lucian Eva, Bogdan Florin Toma, Stefan Lucian Toma,
The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses,
Materiale Plastice,
Volume 55, Issue 1,
2018,
Pages 85-90,
ISSN 2668-8220,
https://doi.org/10.37358/MP.18.1.4969.
(https://revmaterialeplastice.ro/Articles.asp?ID=4969)
Keywords: Spine; Boston orthosis; polypropylene; vertebra


RIS
TY - JOUR
T1 - The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses
A1 - Nanu, Constantin
A2 - Poeata, Ion
A3 - Popescu, Cezar
A4 - Eva, Lucian
A5 - Toma, Bogdan Florin
A6 - Toma, Stefan Lucian
JF - Materiale Plastice
JO - Mater. Plast.
PB - Materiale Plastice SRL
SN - 2668-8220
Y1 - 2018
VL - 55
IS - 1
SP - 85
EP - 90
UR - https://doi.org/10.37358/MP.18.1.4969
KW - Spine
KW - Boston orthosis
KW - polypropylene
KW - vertebra
ER -


BibTex
@article{MatPlast2018P85,
author = {Nanu Constantin and Poeata Ion and Popescu Cezar and Eva Lucian and Toma Bogdan Florin and Toma Stefan Lucian},
title = {The Influence of the Characteristics of Plastic Materials Used in the Performance of the Thoraco-Lumbar Orthoses},
journal = {Materiale Plastice},
volume = {55},
number = {1},
pages = {85-90},
year = {2018},
issn = {2668-8220},
doi = {https://doi.org/10.37358/MP.18.1.4969},
url = {https://revmaterialeplastice.ro/Articles.asp?ID=4969}
}


Downloads number: 0
<<<< back
 
  Search Authors
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License