ABOUT INDEXING EDITORIAL BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER NEWS, EVENTS AUTHOR'S PAGE CONTACT
Materiale Plastice
Cite as: Mater. Plast.
https://doi.org/10.37358/Mat.Plast.1964

OSIM Nr. R102356
ISSN Print 0025-5289
ISSN Online 2668-8220
Materiale Plastice - Latest Issue

Latest Issue >>>
ARCHIVES
   Volume 61, 2024
   Volume 60, 2023
   Volume 59, 2022
   Volume 58, 2021
   Volume 57, 2020
   Volume 56, 2019
   Volume 55, 2018
   Volume 54, 2017
   Volume 53, 2016
   Volume 52, 2015
   Volume 51, 2014
   Volume 50, 2013
   Volume 49, 2012
   Volume 48, 2011
   Volume 47, 2010
   Volume 46, 2009
   Volume 45, 2008
   Volume 44, 2007
   Volume 43, 2006
   Volume 42, 2005
   Volume 41, 2004
   Volume 40, 2003
 
<<<< back

Materiale Plastice (Mater. Plast.), Year 2017, Volume 54, Issue 2, 253-256

https://doi.org/10.37358/MP.17.2.4827

Silvia Izabella Pop, Dana Cristina Bratu, Radu Chiorean, Raluca Adriana Balan, Anamaria Bud, Horatiu Pompiliu Petrescu, Catalin Petru Simon, Mircea Dudescu

Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures


Abstract:
One hundred micro-implants from two different manufacturers were used in the study. From each manufacturer (Link from MISTM and Yesanchor from OrlusTM) the implants were divided in 5 groups: G0 (n=10) new, unused, G1 (n=10) mini-implants inserted in pig bone and removed, ultrasonically cleaned, followed by autoclave sterilization, G2 (n=10) same insertion protocol of group 2 followed by chemical cleaning with phosphoric gel and autoclave strerilization, G3 (n=10) same insertion protocol of group 1 followed by sandblasting and autoclave sterilization, G4 (n=10) same insertion protocol of group 2 followed by cleaning with distilled water and autoclave sterilization. Maximum insertion torque was recorded and subjected to statistical testing. Our results showed significant differences of the maximum insertion torques between groups of Link mini-implant (p=0.006), and no statistical differences of the maximum insertion torques of the Yesanchor implants (p=0.33). Significant differences (p<0.001) were also recorded between the groups of the two types of minii-mplants when compared. Our findings showed that brand-specific differences in maximum insertion torque exist between the two types of mini-implants.


Keywords:
micro-implants; sterilizations; maximum insertion torque

Issue: 2017 Volume 54, Issue 2
Pages: 253-256
Publication date: 2017/6/30
https://doi.org/10.37358/MP.17.2.4827
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
POP, S.I., BRATU, D.C., CHIOREAN, R., BALAN, R.A., BUD, A., PETRESCU, H.P., SIMON, C.P., DUDESCU, M., Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures, Mater. Plast., 54(2), 2017, 253-256. https://doi.org/10.37358/MP.17.2.4827

Vancouver
Pop SI, Bratu DC, Chiorean R, Balan RA, Bud A, Petrescu HP, Simon CP, Dudescu M. Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures. Mater. Plast.[internet]. 2017 Apr;54(2):253-256. Available from: https://doi.org/10.37358/MP.17.2.4827


APA 6th edition
Pop, S.I., Bratu, D.C., Chiorean, R., Balan, R.A., Bud, A., Petrescu, H.P., Simon, C.P. & Dudescu, M. (2017). Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures. Materiale Plastice, 54(2), 253-256. https://doi.org/10.37358/MP.17.2.4827


Harvard
Pop, S.I., Bratu, D.C., Chiorean, R., Balan, R.A., Bud, A., Petrescu, H.P., Simon, C.P., Dudescu, M. (2017). 'Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures', Materiale Plastice, 54(2), pp. 253-256. https://doi.org/10.37358/MP.17.2.4827


IEEE
S.I. Pop, D.C. Bratu, R. Chiorean, R.A. Balan, A. Bud, H.P. Petrescu, C.P. Simon, M. Dudescu, "Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures". Materiale Plastice, vol. 54, no. 2, pp. 253-256, 2017. [online]. https://doi.org/10.37358/MP.17.2.4827


Text
Silvia Izabella Pop, Dana Cristina Bratu, Radu Chiorean, Raluca Adriana Balan, Anamaria Bud, Horatiu Pompiliu Petrescu, Catalin Petru Simon, Mircea Dudescu,
Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures,
Materiale Plastice,
Volume 54, Issue 2,
2017,
Pages 253-256,
ISSN 2668-8220,
https://doi.org/10.37358/MP.17.2.4827.
(https://revmaterialeplastice.ro/Articles.asp?ID=4827)
Keywords: micro-implants; sterilizations; maximum insertion torque


RIS
TY - JOUR
T1 - Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures
A1 - Pop, Silvia Izabella
A2 - Bratu, Dana Cristina
A3 - Chiorean, Radu
A4 - Balan, Raluca Adriana
A5 - Bud, Anamaria
A6 - Petrescu, Horatiu Pompiliu
A7 - Simon, Catalin Petru
A8 - Dudescu, Mircea
JF - Materiale Plastice
JO - Mater. Plast.
PB - Materiale Plastice SRL
SN - 2668-8220
Y1 - 2017
VL - 54
IS - 2
SP - 253
EP - 256
UR - https://doi.org/10.37358/MP.17.2.4827
KW - micro-implants; sterilizations; maximum insertion torque
ER -


BibTex
@article{MatPlast2017P253,
author = {Pop Silvia Izabella and Bratu Dana Cristina and Chiorean Radu and Balan Raluca Adriana and Bud Anamaria and Petrescu Horatiu Pompiliu and Simon Catalin Petru and Dudescu Mircea},
title = {Biochemical Characteristics of Mini-implants Sterilised by Different Chemical and Physical Procedures},
journal = {Materiale Plastice},
volume = {54},
number = {2},
pages = {253-256},
year = {2017},
issn = {2668-8220},
doi = {https://doi.org/10.37358/MP.17.2.4827},
url = {https://revmaterialeplastice.ro/Articles.asp?ID=4827}
}


Downloads number: 0
<<<< back
 
  Search Authors
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License